The U9926 and U2500 Self-Contained Ussing chambers improve on the Classic design by bringing the solution reservoir into the chamber housing. This dramatically reduces the size of the apparatus and increases the ease-of-use of the system.
- Modular design for separate inserts
- No glass circulation reservoirs
- Inserts are quickly exchanged between experiments
- Solution warming is provided by pumping heated water through the chamber halves.
The Self-Contained Ussing Chamber Systems
The Self-Contained Ussing Chambers systems come in single- and dual-channel models and offer many advantages over the Classic design. The single-channel U9926 and dual-channel U2500 are shown to the right. Both systems make use of inserts to secure and position the tissue or culture cup within the chamber body.
Chamber bodies (single- and dual-chamber models) consist of chamber-halves which clamp around the insert(s). Each chamber-half has four ports that enter into its respective bath compartment: a voltage electrode port, a current electrode port, an air/gas port, and a solution drain port. Solution warming is provided by pumping heated water through each chamber-half and there are no delicate glass heat exchangers to be broken. The dual-chamber U2500 has the additional feature of including four needle valves for adjusting the air/gas mixture into each individual chamber-half.
Inserts can be easily exchanged between experiments. Solutions are removed from the chambers through the drain valves and the halves unclamped from each other. The insert is then simply replaced. Inserts are available to support a variety of tissue sizes and culture cups.
Standard Accessories Supplied with U9926 and U2500
The U9926 (single-channel chamber is supplied with 1 electrode set (consisting of 2 voltage and 2 current electrodes), 12 bridge fittings with adapters; and a tubing/ fitting kit. The U2500 (dual channel) chamber is supplied with two each of the above described accessories. Chamber inserts are ordered separately.
The U9926 and U2500 Self-Contained Ussing chambers improve on the Classic design by bringing the solution reservoir into the chamber housing. This dramatically reduces the size of the apparatus and increases the ease-of-use of the system.
- Modular design for separate inserts
- No glass circulation reservoirs
- Inserts are quickly exchanged between experiments
- Solution warming is provided by pumping heated water through the chamber halves.
Each U9926 and U2500 system is supplied with one tissue or culture cup insert. A model letter suffix identifies the insert type.
Insert and culture cup types:
- (A) Round with O-Ring
- (B) Round with Sharp Pins
- (C) Slotted with Pins
- (F) Falcon
- (M) Millicell
- (S) Snapwell
- (T) Transwell.
Each of the above insert types are supplied in various sizes. Consult the table below to select a specific insert and size and include that information with your order.
Type B and C inserts have the pin configurations shown below.

| U9926 and U2500 Systems |
Insert Dimensions |
Insert Model |
| /A |
Round Insert, 3.8 mm, with O-Ring |
U9924A-04 |
| Round Insert, 6.0 mm, with O-Ring |
U9924A-06 |
| Round Insert, 9.0 mm, with O-Ring |
U9924A-09 |
| Round Insert, 12.0 mm, with O-Ring |
U9924A-12 |
| Round Insert, 13.5 mm, with O-Ring |
U9924A-13 |
| /B |
Round Insert, 3.8 mm, with 5 Pins |
U9924B-04 |
| Round Insert, 6.0 mm, with 5 Pins |
U9924B-06 |
| Round Insert, 9.0 mm, with 5 Pins |
U9924B-09 |
| Round Insert, 12.0 mm, with 5 Pins |
U9924B-12 |
| Round Insert, 13.5 mm, with 5 Pins |
U9924B-13 |
| /C |
Slotted Insert, 1.6 x 7.0 mm, with 6 Pins |
U9924C-03 |
| Slotted Insert, 2.4 x 7.0 mm, with 6 Pins |
U9924C-04 |
| Slotted Insert, 3.5 x 7.0 mm, with 6 Pins |
U9924C-05 |
| /F |
Falcon® Adapter, 9 mm |
U9924F-09 |
| Falcon® Adapter, 12 mm |
U9924F-12 |
| Falcon® Adapter, 25 mm |
U9924F-25 |
| /M |
Millicell® Adapter, 12 mm |
U9924M-12 |
| Millicell® Adapter, 30 mm |
U9924M-30 |
| /S |
Snapwell" Adapter, 12mm |
U9924S |
| /T |
Transwell® Adapter, 6.5 mm |
U9924T-06 |
| Transwell® Adapter, 12 mm |
U9924T-12 |
| Transwell® Adapter, 24 mm |
U9924T-24 |
| Order No. |
Model No. |
Description |
Ordering |
| 64-0565 |
U9406 |
Tubing kit (hose and Luer fittings) |
 |
 |
| 64-0554 |
U9975A |
Electrode set, includes 2 Ag/AgCl pellets and 2 Ag wires |
 |
 |
| 64-1521 |
U9565SC |
Electrode bridge fitting kit, pkg of 12 |
 |
 |
| 64-0555 |
U9985 |
Bridge fitting adapters, pkg of 6 |
 |
 |
| 64-0604 |
U9605 |
O-rings for U9926 and U2500 Ussing chambers, 4 pack |
 |
 |
 |
Order No. (Model No.) |
 |
Product Description |
 |
USA Price |
 |
Order |
 |
How to order:
- Select Base Assembly.
Each system includes one or two U9975A Electrode Set(s) and U9965EP Electrode Bridge Fitting Kit(s)
- Select Insert.
Order 1 if using the U9926 and order 2 if using the U2500
----------------------------------------------------------------------------------------------------
|
Base Assembly |
 |
 |
64-0568S (U9926) |
 |
Single-channel Ussing chamber base assembly, does not include insert |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0575S (U2500) |
 |
Dual-channel Ussing chamber base assembly, does not include inserts |
 |
Log In |
 |
Log In |
 |
 |
 |
Inserts for tissue with o-ring |
 |
 |
64-0582 (U9924A-04) |
 |
Tissue insert, 3.8 mm, round with o-ring |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0583 (U9924A-06) |
 |
Tissue insert, 6.0 mm, round with o-ring |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0584 (U9924A-09) |
 |
Tissue insert, 9.0 mm, round with o-ring |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0585 (U9924A-12) |
 |
Tissue insert, 12.0 mm, round with o-ring |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0586 (U9924A-13) |
 |
Tissue insert, 13.5 mm, round with o-ring |
 |
Log In |
 |
Log In |
 |
 |
 |
Inserts for tissue with pins |
 |
 |
64-0587 (U9924B-04) |
 |
Tissue insert, 3.8 mm, round with 5 pins |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0588 (U9924B-06) |
 |
Tissue insert, 6.0 mm, round with 5 pins |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0589 (U9924B-09) |
 |
Tissue insert, 9.0 mm, round with 5 pins |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0590 (U9924B-12) |
 |
Tissue insert, 12.0 mm, round with 5 pins |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0591 (U9924B-13) |
 |
Tissue insert, 13.5 mm, round with 5 pins |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0592 (U9924C-03) |
 |
Tissue insert, 1.6 x 7.0 mm, slotted with 6 pins |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0593 (U9924C-04) |
 |
Tissue insert, 2.4 x 7.0 mm, slotted with 6 pins |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0594 (U9924C-05) |
 |
Tissue insert, 3.5 x 7.0 mm, slotted with 6 pins |
 |
Log In |
 |
Log In |
 |
 |
 |
Inserts for Culture Cup |
 |
 |
64-0600 (U9924S) |
 |
Culture cup insert for Snapwell adapter, 12mm |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0595 (U9924F-09) |
 |
Culture cup insert for Falcon adapter 9mm |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0596 (U9924F-12) |
 |
Culture cup insert for Falcon adapter, 12mm |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0597 (U9924F-25) |
 |
Culture cup insert for Falcon adapter, 25mm |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0598 (U9924M-12) |
 |
Culture cup insert for Millicell adapter, 12mm |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0599 (U9924M-30) |
 |
Culture cup insert for Millicell adapter, 30mm |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0601 (U9924T-06) |
 |
Culture cup insert for Transwell adapter 6.5mm |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0602 (U9924T-12) |
 |
Culture cup insert for Transwell adapter, 12mm |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0603 (U9924T-24) |
 |
Culture cup insert for Transwell adapter, 24mm |
 |
Log In |
 |
Log In |
 |
 |
 |
Replacement Parts |
 |
 |
64-0565 (U9406) |
 |
Tubing kit (hose and Luer fittings) |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-1521 (U9565SC) |
 |
Electrode bridge fitting kit, pkg of 12 |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0554 (U9975A) |
 |
Electrode set, includes 2 Ag/AgCl pellets and 2 Ag wires |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0555 (U9985) |
 |
Bridge fitting adapters, pkg of 6 |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0604 (U9605) |
 |
O-rings for U9926 and U2500 Ussing chambers, 4 pack |
 |
Log In |
 |
Log In |
 |
 |
 |
|
|