This microincubation system operates equally well under both static and continuously perfused situations.
- Uses Peltier technology
- Enables intracellular, whole cell or single channel patch clamp recordings from dissociated cells, cultured cells, and brain slice preparations
- Enables long-term optical examination of living tissue
- Heats or cools both media and gas
-
- Operating temperature ranges from ~5 to 50 °C
When operated with perfusion, the PDMI-2 microincubator has unique design places flexible tubes carrying inflowing perfusate in contact with a temperature regulated Peltier heat pump driven plate, thus heating or cooling the incoming fluid to a command temperature. This eliminates the need for auxiliary preheating or cooling. The Peltier plate also heats or cools the central chamber containing the cells uniformly when no perfusate is flowing.
Flexible Temperature Range
The operating temperature range of the PDMI-2 Open Perfusion Microincubator is nominally 10-14 °C below ambient to 50 °C when used with the TC-202A Temperature Controller but without supplementary water cooling of its fins.
Temperatures as low as 5°C can be achieved by using an optional water carrying Cu coil which attaches to the perimeter fins of the PDMI-2. Temperatures stabilize quickly throughout the operating range and temperature uniformity across the chamber is excellent.
Optimal and Flexible Perfusion
Different modes of operation are possible:
- Static chamber medium at a constant set temperature
- Continuous perfusion at a constant set temperature
- Switching perfusion of extracellular medium at a set temperature
- Discontinuous perfusion
- Rapid temperature changes (with perfusion)
Two temperature controlled perfusion lines deliver perfusate solutions through the microincubator into the chamber a nominal rate of 3 ml per minute each. Fluid level is maintained by placing an aspirator (model LU-ASP) in the chamber.
Fluid height is easily adjusted via a simple screw mechanism. A cleverly designed suction port eliminates fluid flutter thus making for quiet aspiration. A magnetic base secures the aspirator to the microincubator at a user selectable convenient location.
Excellent pH Control
The PDMI-2 also provides gas flow over the top of the chamber for pH control and improved temperature uniformity. The open design provides excellent mechanical and optical access to the media.
Low Noise Conditions
A Teflon well is provided with an Ag-AgCl electrode at its base to allow for the formation of a salt bridge when making low noise electrophysiological recordings.
This microincubation system operates equally well under both static and continuously perfused situations.
- Uses Peltier technology
- Enables intracellular, whole cell or single channel patch clamp recordings from dissociated cells, cultured cells, and brain slice preparations
- Enables long-term optical examination of living tissue
- Heats or cools both media and gas
-
- Operating temperature ranges from ~5 to 50 °C
| Peltier Device Current Rating |
Maximum of 6 amperes continuous at ~3 VDC |
| Temperature Range |
When mounted on a microscope stage the operating temperature ranges from 10-14 °C below ambient to 50 °C using the TC-202A bipolar temperature controller but without any supplementary water cooling of heat fins.
Under the same conditions one can achieve as low as 5°C to 50°C using the TC-202A but also supplying water cooling using an optional Cu coil placed in the fins of the PDMI-2. |
| Temperature Rate of Change |
For a change of ~10° from 22° (sic. ambient) to 32°C with perfusion flow rates ranging from 1-3 mL/min requires about 3 minutes, using the TC-202A bipolar controller. Slower rates (i.e. longer times) would be obtained using a simple VDC supply. |
| Media Perfusion Flow Rate |
Up to 3.0 mL/min under normal conditions. Faster rates are possible if the internal tubing is replaced with either a longer pieces and/or a thinner wall thickness. |
| Thermal Expansion |
± 4 µm between 15° to 30°C
± 20 µm between 30° to 40°C |
| Plastic Perfusate Tubes |
Teflon" tubing |
| Chamber Options |
Corning 35 mm Petri dishes, LU-CSD, MSC-TD or MSC-PTD |
| Recommended Gas Flow |
0.5 to 2.0 L/min |
| Temperature Stability |
± 0.2°C with TC-202A, at 37°C with 1 ml/min perfusion |
| Temperature Gradient |
2°C with 1.5 ml media volume and 1 ml/min perfusion |
| Temperature Sensor |
Thermistor: 100 k©at 25°C - YSI 44011 |
| Dimensions, H x D |
17 x 152 mm (0.67 x 6.0 in) |
| Weight |
0.5 kg (17.9 oz) |
| Microscope Stage Mounting |
Call for options |
| Order No. |
Model No. |
Description |
Ordering |
| 65-0045 |
TC-202A |
Med Systems bipolar temperature controller compatible with PDMI-2, PSMI, CSMI, LU-CB-1, LU-CPC-CEH, and BSC-BU |
 |
 |
| 65-0058 |
PDMI-TUBE |
PDMI-2 copper cooling tube coil (shaped to conform to fin channel) with open ends |
 |
 |
| 65-0093 |
PDMI ARL |
PDMI-2 stage adapter for Leica, 88.0 mm OD x 1.8 mm thick |
 |
 |
| 65-0059 |
PDMI ARN |
PDMI-2 stage adapter for Nikin, 107.8 mm OD x 1.8 mm thick |
 |
 |
| 65-0093 |
PDMI ARO |
PDMI-2 stage adapter for Olympus 109.8 mm OD x 1.8 mm thick |
 |
 |
| 65-0093 |
PDMI ARZ |
PDMI-2 stage adapter for Zeiss, 102.8 mm OD x 1.8 mm thick |
 |
 |
 |
Order No. (Model No.) |
 |
Product Description |
 |
USA Price |
 |
Order |
 |
 |
 |
65-0043 (PDMI-2) |
 |
Open perfusion microincubator, comes with LU-PD and LU-ASP (microscope stage adapter not included) |
 |
Log In |
 |
Log In |
 |
 |
 |
Accessories |
 |
 |
65-0045 (TC-202A) |
 |
Med Systems bipolar temperature controller compatible with PDMI-2, PSMI, CSMI, LU-CB-1, LU-CPC-CEH, and BSC-BU |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0058 (PDMI-TUBE) |
 |
PDMI-2 copper cooling tube coil (shaped to conform to fin channel) with open ends |
 |
Log In |
 |
Log In |
 |
 |
 |
Dishes and Holders |
 |
 |
65-0049 (LU-CSD-Special) |
 |
Leiden multi well cover slip dish; 35 mm D Teflon dish with two (2) kidney-shaped inner optical window wells |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0050 (MSC-PTD) |
 |
Teflon Glass Cover Slip Dish; 35 mm D, 9.5 x 19 mm (W x L) Rectangular Optical Window |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0051 (MSC-TD) |
 |
Teflon Glass Cover Slip Dish; 35 mm D with removable handle, 35 mm D teflon dish, 19 mm D optical window |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0054 (LU-PD) |
 |
Sleeve of 35 mm Petri dishes, pkg. of 20 |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0047 (LU-ASP) |
 |
Leiden aspirator, cover slip dish fluid level setting device, 38 mm H |
 |
Log In |
 |
Log In |
 |
 |
 |
Alignment Rings and Fixing Platforms |
 |
 |
65-0093 (PDMI-ARL) |
 |
Alignment ring for Leica microscope, 8 x 1.8 mm (OD x thickness) |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0059 (PDMI-ARN) |
 |
PDMI-2/PSMI alignment ring for Nikon Diaphot (Old or 300/200) TMD Stage, 4.242 x .071 in (D x Thickness) |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0060 (PDMI-ARO) |
 |
PDMI-2/PSMI alignment ring for Olympus IX-50/70 or IMT2 Fixed Stage, 4.320 x .071 in (D x Thickness) |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0061 (PDMI-ARZ) |
 |
PDMI-2/PSMI alignment ring for Zeiss Axiovert Gliding or Rotary Stages, 4.046 x .071 in (D x Thickness) |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0062 (PDMI-FPL) |
 |
PDMI-2/PSMI fixing platform for Leica DAS Mikroskop DMIL and DMIRB/E with attachable mechanical Stage |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0063 (PDMI-FPZ) |
 |
PDMI-2/PSMI fixing platform for Zeiss Axiovert with attachable mechanical stage, MType Stage |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0058 (PDMI-TUBE) |
 |
PDMI-2 copper cooling tube coil (shaped to conform to fin channel) with open ends |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0064 (LU-FPL) |
 |
LU-CB-1 fixing platform for Leica DAS Mikroskop DMIL and DMIRB/E with attachable mechanical stage |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0065 (LU-FPZ) |
 |
LU-CB-1 fixing platform for Zeiss Axiovert with attachable mechanical stage, mtype stage |
 |
Log In |
 |
Log In |
 |
 |
 |
Thermistors |
 |
 |
65-0057 (BSC-T3) |
 |
Bath thermistor for use with PDMI-2, PSMI, LU-CB-1, and TC-202A |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0056 (BSC-T3A) |
 |
Bath thermistor for use with LU-CPC-CEH and TC-202A |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0098 (BSC-T2) |
 |
Replacement T2 bath thermistor for obsolete TC-102 |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0016 (BSC-T2A) |
 |
Replacement bath thermistor for use with LU-CPC-CEH and TC-102 |
 |
Log In |
 |
Log In |
 |
 |
 |
Miscellaneous |
 |
 |
65-0047 (LU-ASP) |
 |
Leiden aspirator, cover slip dish fluid level setting device, 38 mm H |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0052 (MI-M) |
 |
Mini magnets for top surface of microincubators (LU-CB-1, PDMI-2 or PSMI), set of 4 |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0055 (BSC-TH) |
 |
Magnetic thermistor holder for LU-CB-1 thermistors |
 |
Log In |
 |
Log In |
 |
 |
 |
Microincubator Replacement Parts |
 |
 |
65-0066 (D-ORING-1) |
 |
Replacement cover slip dish o-rings for LU-CSD or MS-CTD, small (23.80 mm OD) and large (29.80 mm OD) (2) |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0067 (D-ORING-2) |
 |
Replacement cover slip dish o-rings for MSC-PTD, small (20.80 mm OD) and large (29.80 mm OD) (2) |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
64-0705 (CS-25R) |
 |
Round cover glass, #1 thickness, 25 mm, 100 pack |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0069 (CS-GLASS-2) |
 |
Glass cover slips (#2) for LU-CSD or MSC-PTD, 0.180.25 mm thickness, 25 mm OD, 100 pack |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0070 (MI-T) |
 |
Replacement perfusion/aspiration teflon tubing for PDMI-2 or PSMI, 2 ft L x 26 AWG (8) |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0071 (LU-CPC-P) |
 |
Silicone rubber plugs for LU-CPC or LU-CPC-CEH (4) |
 |
Log In |
 |
Log In |
 |
 |
 |
 |
 |
65-0072 (TC-CA) |
 |
Replacement output cable to connect TC-102 Temperature Controller to LU-CB-1 or LU-CPC-CEH |
 |
Log In |
 |
Log In |
 |
 |
 |
|
|