Multi-line in-line solution heating is the simplest and most effective method of warming multiple perfusion solutions to the same temperature.
In-line solution heating is the simplest and most effective method of warming perfusion solutions. The minimal dead space manifold at the output of the in-line solution heater allows it to be used in any application where from 2 to 8 perfusion lines are required to be connected to a chamber or other device.
The output from the heater is connected to the chamber using a short length of tubing such that the warmed perfusate flows directly into the chamber bath. Connections are made by press fitting PE-160 tubing onto the 18 gauge stainless steel hypodermic tubes. Cap plugs are supplied to block any unused inputs.
Depending on bath volume and other factors, inline solution heating itself may be sufficient for many applications. (Solution reservoir heaters from Warner Instruments are recommended if outgassing of solutions is a problem.) The SHM Series heaters will accommodate flow rates up to 5 mL/min while maintaining 37°C.
Each heater is supplied with a TA-29 thermistor cable assembly (shown on the right) which allows for monitoring the actual bath temperature (T2 output on the heater controller), and 3 meters of PE-160 tubing. Both are compatible with Warner's TC-344C and TC-324C temperature controllers.
Heater Resistance | 10Ω |
---|---|
Voltage Requirement | Variable 0 to 12 VDC max. |
Maximum Temperature | 65°C |
Internal Dead Volume | 94 µL |
Manifold Dead Volume | 30 µL (manifold input to output) |
Maximum Flow Rate at 37°C | |
SHM-6 | 5 mL/min |
SHM-8 | 5 mL/min |
Physical Dimensions | |
Body | 16.5 mm x 165 (D x L) |
Cable | 1.9 m |
Weight | 104 g |
Warranty | 1 year |
Temperature of 37°C can be maintained at ± 0.2°C under following conditions: | |
Condition A | Solution temperature at input (nominally 21°C) varies no more than ±10% |
Condition B | Solution flow rate varies no more than 25% with 5 mL min/max flow rate |
Order No. | Model No. | Product Description | USA Price | Order |
---|---|---|---|---|
64-0107 | TA-29 | Cable with bead thermistor | Login | Login |
64-0108 | TA-30 | Cable with glass thermistor | Login | Login |
64-0755 | PE-160/10 | Polyethylene tubing, PE-160, 10 ft | Login | Login |
64-2401 | TC-344C | Heater controller, dual channel, 110-230 VAC, 50/60Hz | Login | Login |
64-2400 | TC-324C | Heater controller, single channel, 110-230 VAC, 50/60Hz | Login | Login |
References
(SH-27B, SF-28) Single Inline Solution Heaters
PH & P Series 20 Platforms
(QE-1) Quick Exchange Platform for 35-40 mm dishes
(DH-35) Culture Dish Heater
(DH-35iL) Culture Dish Incubator
(SHH) In-line Solution Heater Holders
(SHM-828) Eight Line In-Line Solution Heater
Heating and Cooling: Application Fundamentals
Customers from Europe and Australia can use the Multi Channel Systems - Online Shop to order Warner products or create quotes.
Order No. | Model No. | Product Description | USA Price | Order |
---|---|---|---|---|
64-0104 | SHM-6 | Line In-Line Solution Heaters (SHM-6, SHM-Six-line solution heater | Login | Login |
64-0105 | SHM-8 | Line In-Line Solution Heaters (SHM-6, SHM-Eight-line solution heater | Login | Login |
Accessories and Replacement Parts | ||||
64-0060 | MB-B | Magnetic base; main pole (12 x 176 mm, D x L), Sub Pole (10 x 165 mm, D x L), 800 N hold force, MM-33 compatible | Login | Login |
64-0107 | TA-29 | Cable with bead thermistor | Login | Login |
64-0755 | PE-160/10 | Polyethylene tubing, PE-160, 10 ft | Login | Login |
64-0108 | TA-30 | Cable with glass thermistor | Login | Login |
64-2400 | TC-324C | Heater controller, single channel, 110-230 VAC, 50/60Hz | Login | Login |
64-2401 | TC-344C | Heater controller, dual channel, 110-230 VAC, 50/60Hz | Login | Login |