Choose between fully manual or fully digital mixers.
Three Gas Mixer / (3GF Mixer-Hypoxia) Manual CO2 - Manual N2 - Manual Air
The 3GF Mixer-Hypoxia is a 3 gas mixer (Carbon Dioxide, Nitrogen, Air) which employs floating ball flow meters.
Three Gas Mixer / (3GF Mixer-Hyperoxia) Manual CO2 - Manual N2 - Manual Air
The 3GF Mixer-Hypoxia is a 3 gas mixer (Carbon Dioxide, Nitrogen, Air) which employs floating ball flow meters.
CO2-O2 UNIT-BL CP
Designed to supply desired Air-CO2 or N2-O2-CO2 mixture at controlled pressure.
The Bold Line Three Gas Mixer is designed to replace pre-mixed tanks or compressed gas lines and a single unit can supply up to 10 microscope incubators.
The device can mix two or three gases, according to operator's need.
A long life zirconium oxide sensor precisely measures the O2 concentration, while a non dispersive InfraRed (NDIR) dual wave length detector sets the CO2 concentration. Operation is via an easy to use touch screen interface, OKOTouch.
An optional Smart Box data logger and web server allows operation via any web-enabled device. The system may also be operated via a PC using OKO-Control 2.0 software or Nis Elements software.
Sensor calibration is made with an external meter or calibration gas.
Note: Order Single floating ball flowmeters along with the Multi-user controller, one for each incubator to be connected.
The Bold Line combination CO2 - O2 gas controllers are ideal for hypoxia and hyperoxia experiments.
The Bold Line combination CO2 - O2 gas controllers are ideal for hypoxia and hyperoxia experiments. Two versions are available, CO2; 0-10% and O2; 1-18%, and CO2; 0-20% and O2; 1-95%.
Gas flow rates are digitally controlled. A long life zirconium oxide sensor precisely measures the O2 concentration, a non dispersive InfraRed (NDIR) dual wave length detector sets the CO2 concentration.
Operation is via an easy to use touch screen interface, OKO-Touch. An optional Smart Box data logger and web server allows operation via any web-enabled device. The system may also be operated via a PC using OKO-Control 2.0 software or Nis Elements software.
Sensor calibration is made with an external meter or calibration gas.
Bold Line Specifications
CO2-O2 UNIT-BL [0-20;1-95]
Output pressure | 1-4 atm (absolute pressure) |
---|---|
Pressurized Vessel | 5 L |
Operating mode | Adds CO2 and air to N2 |
Concentration range | CO2 range: 4-8%, O2 range: 3-7% |
CO2 Accuracy | ± 5% of CO2 concentration, i.e. ± 0.25% at 5%CO2 |
O2Accuracy | 0.1% at 5%O2 |
Set Point Resolution | 0.1% |
CO2 Repeatability | Better than 0.1% |
O2 Repeatability | 0.05% of O2 |
Total flow rate | 0.5 Nl/min (at 4 ata) |
CO2 consumption | (at 6% of CO2): 0.042 Nl/min |
Air consumption | (at 6% of CO2 and 5% O2): 0.167 Nl/min |
N2 consumption | (at 5% of 02) 0.5 Nl/min |
CO2 sensor | 10 year-life Non Dispersive InfraRed (NDIR) dual wave length detector |
O2 sensor | 10 year-life zirconium oxide sensor |
Filtering device | PTFE membrane with 0.2 μm pores |
Bold Line CO2 - O2 Controller Specifications
CO2-O2 UNIT-BL [0-10;1-18]
Operating mode | Adds CO2 and N2 to Air |
---|---|
Concentration range | CO2 range: 0-10%, O2 range: 1-18% |
CO2 Accuracy | ± 5% of CO2 concentration, i.e. ± 0.25% at 5%CO2 |
O2Accuracy | 0.1% at 5%O2 |
Set Point Resolution | 0.1% |
CO2 Repeatability | Better than 0.1% |
O2 Repeatability | 0.05% of O2 |
Total flow rate | 0.4 Nl/min - constant |
Outlet pressure | Ambient |
CO2 consumption (at 5%) | 0.02 Nl/min |
N2 consumption (at 5% of 02) | 0.3 Nl/min |
CO2 sensor | 10 year-life Non Dispersive InfraRed (NDIR) dual wave length detector |
O2 sensor | 10 year-life zirconium oxide sensor |
Filtering device | PTFE membrane with 0.2 μm pores |
CO2-O2 UNIT-BL [0-20;1-95]
Operating mode | Mixes CO2, O2 and N2 |
---|---|
Concentration range | CO2 range: 0-20%, O2 range: 1-95% |
CO2 Accuracy | ± 0.3 % at 5% CO2 and 5% O2 |
O2Accuracy | ± 0.2% at 5% CO2 and 5% CO2 |
Set Point Resolution | 0.1% |
Total flow rate | 0.35 Nl/min - constant |
Outlet pressure | Ambient |
CO2 consumption | (at 5% of CO2): 0.0175 Nl/min |
O2 consumption | (at 5% of O2): 0.0175 Nl/min |
N2 consumption | (at 5% of CO2 and at 5% of O2): 0.315 Nl/min |
Digital Flow Meters | CMOS Sensors |
CO2 sensor | 10 year-life Non Dispersive InfraRed (NDIR) dual wave length detector |
O2 sensor | 10 year-life zirconium oxide sensor |
Filtering device | PTFE membrane with 0.2 μm pores |
Customers from Europe and Australia can use the Multi Channel Systems - Online Shop to order Warner products or create quotes.
Order No. | Model No. | Product Description | USA Price | Order |
---|---|---|---|---|
Manual Mixer | ||||
64-1997 | 3GF-Mixer-Hypoxia | 3 Gas mixer, Air Nitrogen and CO2, O2-2-20% | Login | Login |
64-1998 | 3GF-Mixer-Hyperoxia | 3 Gas mixer, Air Nitrogen and CO2, O2-40-85% | Login | Login |
Bold Line Multi-User | ||||
64-2004 | CO2-O2 Unit-BL CP | Bold Line N2 / CO2 / O2 gas controller, multi-user. CO2 range from 4-8%, O2 range from 3-7% | Login | Login |
64-2965 | Oko-Touch | Touch screen display for Bold Line controllers | Login | Login |
Bold Line CO2 - O2 | ||||
64-2003 | CO2-O2 Unit-BL[1-20:1-95] | Bold Line CO2 / O2 controller for hypoxia and hyperoxia. CO2 to 20%, O2 to 95% | Login | Login |
Accessories and Replacement Parts | ||||
64-1999 | OKO-AP | Air Pump | Login | Login |
64-2008 | SM-BL | Smart Box (data logger, web server, and remote assistant) for Bold Line controllers | Login | Login |
64-2962 | OKO-AP-BL | Bold Line Air Pump, max pressure 300 mbar | Login | Login |