Specialized Tools for Electrophysiology and Cell Biology Research

UssingChart Data Acquisition for Epithelial Transport

Product Summary

Data acquisition system specifically configured for epithelial transport (Ussing) studies

  • Includes amplifiers, digitizer, software, and all cables
  • Available in 2, 4, 6, and 8 channel systems
  • Easily expanded up to 8 channels
  • Runs under Windows and Mac OS
  • Free software updates

The UssingChart data acquisition package is a complete system that includes EC-825A amplifier(s), LIH 8+8 digitizer(s), UssingChart software, and all needed connecting cables. It's natively available in 2, 4, 6, or 8 channels and can be easily scaled up to its full capacity of eight channels.

UssingChart Software

The UssingChart software is the heart of the system and allows for full control of the amplifiers during acquisition. Data is displayed in real time and is saved for later review or export. Exported data is compatible with a wide variety of data analysis and graphing programs.

The UssingChart software is based on HEKA's Chartmaster and has been fully configured specifically for epithelial research applications. Furthermore, perpetual software updates are available via the Chartmaster section of the HEKA website.

ussingchart_screenshot

EC-825A Epithelial Voltage Clamp Amplifier

The EC-825A is specifically designed for studies of epithelial transport and the electrical properties of tissue. It features high common mode rejection, multiple clamp speed selection, membrane resistance measurement circuitry, and a watertight headstage that includes a model membrane.

Detailed description and specifications can be found on our EC-825A page.

641605_EC825A_FP_BA

LIH 8+8 Digitizer

The UssingChart software is specifically designed to work with HEKA's LIH 8+8 digitizer. The LIH 8+8 is a high resolution, low-noise scientific data acquisition apparatus that utilizes the latest USB 2.0 and high speed processing technologies. The sample rate is up to 200 KHz and two LIH's can be linked, which doubles the number of analog inputs and outputs.

Detailed description and specifications can be found at HEKA Data Acquisition.

LIH-88

System Expandability

UssingChart dtata systems can be easily expanded. Refer to the chart below for needed components:

Expansion Needed items Order No. Quantity to order
2 to 4 channels
  EC-825A dual channel epithelial voltage clamp 64-1605 1
2 to 6 channels - order all items
  EC-825A dual channel epithelial voltage clamp 64-1605 2
  LIH 8+8 digitizer 89-5035 1
  Dual EC-825A DAQ cable 64-3009 1
  LIH master/slave cable 89-5244 1
2 to 8 channels - order all items
  EC-825A dual channel epithelial voltage clamp 64-1605 3
  LIH 8+8 digitizer 89-5035 1
  Dual EC-825A DAQ cable 64-3009 1
  LIH master/slave cable 89-5244 1
4 to 6 channels - order all items
  EC-825A dual channel epithelial voltage clamp 64-1605 1
  LIH 8+8 digitizer 89-5035 1
  Dual EC-825A DAQ cable 64-3009 1
  LIH master/slave cable 89-5244 1
4 to 8 channels - order all items
  EC-825A dual channel epithelial voltage clamp 64-1605 2
  LIH 8+8 digitizer 89-5035 1
  Dual EC-825A DAQ cable 64-3009 1
  LIH master/slave cable 89-5244 1
6 to 8 channels
  EC-825A dual channel epithelial voltage clamp 64-1605 1

Detailed description and specifications for the EC-825A can be found on the EC-825A webpage.

Detailed description and specifications for the LIH 8+8 can be found at HEKA Data Acquisition webpage.

Pricing Top Description

All UssingChart DAQ Packages include:
EC-825A amplifier(s), LIH 8+8 digitizer(s), UssingChart software, and cables

 

Order No. Model No. Product Description USA Price Order
2 Channel UssingChart Package

    - order 1 of each

64-3009 EC-825A cable, dual - fits 2 amplifiers (4 acquisition channels) Login Login
64-1605 EC-825A Dual channel epithelial voltage clamp, ±50V compliance, 110-250 VAC Login Login
89-5285 UssingChart software Login Login
64-3008 EC-825A cable, single - fits 1 amplifier (2 acquisition channels) Login Login
4 Channel UssingChart Package

   - order 2 of 64-1605; 1 each of the rest

64-3009 EC-825A cable, dual - fits 2 amplifiers (4 acquisition channels) Login Login
64-1605 EC-825A Dual channel epithelial voltage clamp, ±50V compliance, 110-250 VAC Login Login
89-5285 UssingChart software Login Login
89-5035 LIH 8+8 LIH 8+8 computer interface, 90-250 VAC, 50/60 Hz, CE Login Login
6 Channel UssingChart Package

   - order 3 of 64-1605; 2 each of 89-5035 and 64-3009; 1 each of the rest

64-3009 EC-825A cable, dual - fits 2 amplifiers (4 acquisition channels) Login Login
89-5244 LIH master/slave connecting cable Login Login
64-1605 EC-825A Dual channel epithelial voltage clamp, ±50V compliance, 110-250 VAC Login Login
89-5285 UssingChart software Login Login
8 Channel UssingChart Package

   - order 4 of 64-1605; 2 each of 89-5035 and 64-3009; 1 each of the rest

64-3009 EC-825A cable, dual - fits 2 amplifiers (4 acquisition channels) Login Login
64-1605 EC-825A Dual channel epithelial voltage clamp, ±50V compliance, 110-250 VAC Login Login
89-5285 UssingChart software Login Login
Replacement Cables
64-3009 EC-825A cable, dual - fits 2 amplifiers (4 acquisition channels) Login Login
89-5244 LIH master/slave connecting cable Login Login
Upgrade 2 to 6 channels - order 2 of 64-1605, 1 each of the rest
64-3009 EC-825A cable, dual - fits 2 amplifiers (4 acquisition channels) Login Login
89-5244 LIH master/slave connecting cable Login Login
64-1605 EC-825A Dual channel epithelial voltage clamp, ±50V compliance, 110-250 VAC Login Login
Upgrade 2 to 8 channels - order 3 of 64-1605, 1 each of the rest
64-3009 EC-825A cable, dual - fits 2 amplifiers (4 acquisition channels) Login Login
64-1605 EC-825A Dual channel epithelial voltage clamp, ±50V compliance, 110-250 VAC Login Login
Upgrade 4 to 6 channels - order 1 of each
64-3009 EC-825A cable, dual - fits 2 amplifiers (4 acquisition channels) Login Login
89-5244 LIH master/slave connecting cable Login Login
64-1605 EC-825A Dual channel epithelial voltage clamp, ±50V compliance, 110-250 VAC Login Login
Upgrade 4 to 8 channels - order 2 of 64-1605, 1 each of the rest
64-3009 EC-825A cable, dual - fits 2 amplifiers (4 acquisition channels) Login Login
89-5244 LIH master/slave connecting cable Login Login
64-1605 EC-825A Dual channel epithelial voltage clamp, ±50V compliance, 110-250 VAC Login Login
Upgrade 2 to 4 channels - order 1
64-1605 EC-825A Dual channel epithelial voltage clamp, ±50V compliance, 110-250 VAC Login Login
Upgrade 6 to 8 channels - order 1
64-1605 EC-825A Dual channel epithelial voltage clamp, ±50V compliance, 110-250 VAC Login Login

Need support?

Want to know more about our quality products or need assistance in technical support?

TALK TO OUR EXPERTS